{"created":"2024-10-23T10:17:54.563798+00:00","id":2002208,"links":{},"metadata":{"_buckets":{"deposit":"208d3cd1-8977-444b-b880-a8a69d541092"},"_deposit":{"created_by":7,"id":"2002208","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"2002208"},"status":"published"},"_oai":{"id":"oai:tokushima-u.repo.nii.ac.jp:02002208","sets":["1713853213384:1713853295607"]},"author_link":["1551","284","426"],"item_10001_biblio_info_7":{"attribute_name":"bibliographic_information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1-2","bibliographicPageEnd":"78","bibliographicPageStart":"69","bibliographicVolumeNumber":"59","bibliographic_titles":[{"bibliographic_title":"The journal of medical investigation : JMI","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose : To compare visual outcomes, intraoperative and postoperative complications of 25-gauge transconjunctival sutureless vitrectomy (25-G TSV) versus conventional 20-gauge vitrectomy in epiretinal membrane (ERM) surgery. Methods : A retrospective comparative study was conducted on 200 eyes with idiopathic ERM who underwent either primary 20-gauge vitrectomy (n=95) or 25-G TSV (n=105) with 6 months follow up. The following parameters were collected and compared : age, gender, best corrected visual acuity (BCVA), intraocular pressure (IOP), postoperative anterior chamber inflammation, intraoperative and postoperative complications. Results : Twenty-five gauge group achieved a significantly better vision at the 1st postoperative month (p=0.008) and a significantly higher incidence of visual improvement 6 months postoperatively (p=0.04) than 20-gauge group. Intraocular pressure was significantly higher at the 1st, 3rd and 6th postoperative months compared with baseline in the 20-G group. However, in the 25-gauge group IOP remained near to the baseline at the same period. Twenty five-gauge group achieved a significantly lower anterior chamber inflammation and a lower incidence of postoperative cystoid macular edema (CME) (p=0.01), hyphema (p=0.000) and after cataract (p=0.000) than 20-gauge group. Conclusions : The 25-gauge sutureless vitrectomy achieves rapid and higher visual improvement, less postoperative inflammation and complications than the 20-gauge vitrectomy in ERM surgery.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_source_id_9":{"attribute_name":"収録物ID","attribute_value_mlt":[{"subitem_source_identifier":"13431420","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AA11166929","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1715043197608":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access"}]},"item_1723180141928":{"attribute_name":"item_1723180141928","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"264948"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sayed, Khulood Mohammed","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"ナイトウ, タケシ","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1551","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Farouk, Mahmoud Mohamed","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"ナガサワ, トシヒコ","creatorNameLang":"ja"},{"creatorName":"ナガサワ, トシヒコ","creatorNameLang":"ja-Kana"},{"creatorName":"Nagasawa, Toshihiko","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"香留, 崇","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"284","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Abd El-Latif, Ismail Mousa","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Abdallah, Ahmad Mostafa","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Mohamed, Usama Ali","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"三田村, 佳典","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"426","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2014-02-05"}],"displaytype":"detail","filename":"LID201402042003.pdf","filesize":[{"value":"310 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://tokushima-u.repo.nii.ac.jp/record/2002208/files/LID201402042003.pdf"},"version_id":"79b9eaef-2b8c-48f4-86ed-1cf035ca5f17"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"20-gauge vitrectomy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"25-gauge transconjunctival sutureless vitrectomy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"epiretinal membrane","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"microcannulas","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"item_resource_type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Twenty five-gauge sutureless vitrectomy versus 20-gauge vitrectomy in epiretinal membrane surgery","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Twenty five-gauge sutureless vitrectomy versus 20-gauge vitrectomy in epiretinal membrane surgery","subitem_title_language":"en"}]},"item_type_id":"40001","owner":"7","path":["1713853295607"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-02-04"},"publish_date":"2014-02-04","publish_status":"0","recid":"2002208","relation_version_is_last":true,"title":["Twenty five-gauge sutureless vitrectomy versus 20-gauge vitrectomy in epiretinal membrane surgery"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2024-10-28T01:33:32.240419+00:00"}