{"created":"2024-10-28T03:14:44.399706+00:00","id":2004418,"links":{},"metadata":{"_buckets":{"deposit":"cbb812a1-acff-471d-9b6e-ba69124755e0"},"_deposit":{"created_by":7,"id":"2004418","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"2004418"},"status":"published"},"_oai":{"id":"oai:tokushima-u.repo.nii.ac.jp:02004418","sets":["1713853213384:1713853295607"]},"author_link":["355"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-07-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"850","bibliographicPageStart":"847","bibliographicVolumeNumber":"24","bibliographic_titles":[{"bibliographic_title":"Analytical Sciences","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A portable instrument for two-dimensional X-ray fluorescence imaging was assembled with an X-ray source using a pyroelectric crystal, which was driven by a 9-V dry battery, a Si-PIN detector, a slit, and pulse motors. Line scanning for a mug and a knife-edge-scan of an iron sheet were carried out using this spectrometer. The sensitivity of the spectrometer was sufficient for elemental analysis of a mug using a 1 mm2 slit, and several elements, such as Co, Ni, Zn, Pb and Zr, were detected. The estimated spatial resolution using a 0.8-mm pinhole was 3.5 mm. ","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society for Analytical Chemistry","subitem_publisher_language":"en"}]},"item_10001_rights_15":{"attribute_name":"権利情報","attribute_value_mlt":[{"subitem_rights":"© 2008 by The Japan Society for Analytical Chemistry ","subitem_rights_language":"en"}]},"item_10001_source_id_9":{"attribute_name":"収録物ID","attribute_value_mlt":[{"subitem_source_identifier":"13482246","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"09106340","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AA12022210","subitem_source_identifier_type":"NCID"},{"subitem_source_identifier":"AA10500785","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1715043197608":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access"}]},"item_1722929371688":{"attribute_name":"出版社版DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_language":"ja","subitem_relation_name_text":"10.2116/analsci.24.847"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.2116/analsci.24.847","subitem_relation_type_select":"DOI"}}]},"item_1723180141928":{"attribute_name":"EID","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"228452"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"ハタケヤマ, ソウ","creatorNameLang":"ja"},{"creatorName":"ハタケヤマ, ソウ","creatorNameLang":"ja-Kana"},{"creatorName":"Hatakeyama, So","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"クニムラ, シンスケ","creatorNameLang":"ja"},{"creatorName":"クニムラ, シンスケ","creatorNameLang":"ja-Kana"},{"creatorName":"Kunimura, Shinsuke","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"ササキ, ノブハル","creatorNameLang":"ja"},{"creatorName":"ササキ, ノブハル","creatorNameLang":"ja-Kana"},{"creatorName":"Sasaki, Nobuharu","creatorNameLang":"en"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"山本, 孝","creatorNameLang":"ja"},{"creatorName":"ヤマモト, タカシ","creatorNameLang":"ja-Kana"},{"creatorName":"Yamamoto, Takashi","creatorNameLang":"en"}],"familyNames":[{"familyName":"山本","familyNameLang":"ja"},{"familyName":"ヤマモト","familyNameLang":"ja-Kana"},{"familyName":"Yamamoto","familyNameLang":"en"}],"givenNames":[{"givenName":"孝","givenNameLang":"ja"},{"givenName":"タカシ","givenNameLang":"ja-Kana"},{"givenName":"Takashi","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"355","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"185743/profile-ja.html","nameIdentifierScheme":"徳島大学 教育研究者総覧","nameIdentifierURI":"http://pub2.db.tokushima-u.ac.jp/ERD/person/185743/profile-ja.html"},{"nameIdentifier":"70361756","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://nrid.nii.ac.jp/ja/search/?qm=70361756"}]},{"creatorNames":[{"creatorName":"カワイ, ジュン","creatorNameLang":"ja"},{"creatorName":"カワイ, ジュン","creatorNameLang":"ja-Kana"},{"creatorName":"Kawai, Jun","creatorNameLang":"en"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2018-03-16"}],"displaytype":"detail","filename":"analsci_24_7_847.pdf","filesize":[{"value":"610 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://tokushima-u.repo.nii.ac.jp/record/2004418/files/analsci_24_7_847.pdf"},"version_id":"f877b2d9-0cb2-45cb-be9d-853d300a7cce"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Spatially Resolved X-ray Fluorescence Analysis with a Pyroelectric X-ray Emitter","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Spatially Resolved X-ray Fluorescence Analysis with a Pyroelectric X-ray Emitter","subitem_title_language":"en"}]},"item_type_id":"40001","owner":"7","path":["1713853295607"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-03-16"},"publish_date":"2018-03-16","publish_status":"0","recid":"2004418","relation_version_is_last":true,"title":["Spatially Resolved X-ray Fluorescence Analysis with a Pyroelectric X-ray Emitter"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2025-01-28T00:10:59.220079+00:00"}