{"created":"2024-10-28T06:07:36.794326+00:00","id":2005134,"links":{},"metadata":{"_buckets":{"deposit":"7d5c4d0e-28cf-479a-af3d-61f70cee4358"},"_deposit":{"created_by":7,"id":"2005134","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"2005134"},"status":"published"},"_oai":{"id":"oai:tokushima-u.repo.nii.ac.jp:02005134","sets":["1713853213384:1713853295607"]},"author_link":["1677","1714","1703","268","589"],"control_number":"2005134","item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-01-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"219","bibliographicPageStart":"213","bibliographicVolumeNumber":"60","bibliographic_titles":[{"bibliographic_title":"Journal of Prosthodontic Research","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Patients: Titanium has been considered to be a non-allergenic material. However, several studies have reported cases of metal allergy caused by titanium-containing materials. We describe a 69-year-old male for whom significant pathologic findings around dental implants had never been observed. He exhibited allergic symptoms (eczema) after orthopedic surgery. The titanium screws used in the orthopedic surgery that he underwent were removed 1 year later, but the eczema remained. After removal of dental implants, the eczema disappeared completely.\nDiscussion: Titanium is used not only for medical applications such as plastic surgery and/or dental implants, but also for paints, white pigments, photocatalysts, and various types of everyday goods. Most of the usage of titanium is in the form of titanium dioxide. This rapid expansion of titanium-containing products has increased percutaneous and permucosal exposure of titanium to the population.\nConclusions: In general, allergic risk of titanium material is smaller than that of other metal materials. However, we suggest that pre-implant patients should be asked about a history of hypersensitivity reactions to metals, and patch testing should be recommended to patients who have experienced such reactions.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Japan Prosthodontic Society","subitem_publisher_language":"en"}]},"item_10001_rights_15":{"attribute_name":"権利情報","attribute_value_mlt":[{"subitem_rights":"© 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).","subitem_rights_language":"en"}]},"item_10001_source_id_9":{"attribute_name":"収録物ID","attribute_value_mlt":[{"subitem_source_identifier":"18839207","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"18831958","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AA12395171","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1715043197608":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access"}]},"item_1722929371688":{"attribute_name":"出版社版DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_language":"ja","subitem_relation_name_text":"10.1016/j.jpor.2015.12.004"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1016/j.jpor.2015.12.004","subitem_relation_type_select":"DOI"}}]},"item_1723180141928":{"attribute_name":"EID","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"306060"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"細木, 眞紀","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1677","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西川, 啓介","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1714","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮本, 洋二","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1703","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大江, 剛","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"268","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松香, 芳三","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"589","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2018-07-25"}],"displaytype":"detail","filename":"jpor_60_3_213.pdf","filesize":[{"value":"2.25 MB"}],"format":"application/pdf","licensetype":"license_5","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://tokushima-u.repo.nii.ac.jp/record/2005134/files/jpor_60_3_213.pdf"},"version_id":"35b30032-06d7-4587-8251-dcc2891ac74e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Titanium","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Dental implants","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Metal allergy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Patch testing","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Orthopedic surgery","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Allergic contact dermatitis caused by titanium screws and dental implants","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Allergic contact dermatitis caused by titanium screws and dental implants","subitem_title_language":"en"}]},"item_type_id":"40001","owner":"7","path":["1713853295607"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-07-25"},"publish_date":"2018-07-25","publish_status":"0","recid":"2005134","relation_version_is_last":true,"title":["Allergic contact dermatitis caused by titanium screws and dental implants"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2024-12-18T04:33:51.351588+00:00"}