{"created":"2024-10-28T08:29:26.012379+00:00","id":2006258,"links":{},"metadata":{"_buckets":{"deposit":"301c1c09-232e-471a-afe4-50426b3dcef9"},"_deposit":{"created_by":7,"id":"2006258","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"2006258"},"status":"published"},"_oai":{"id":"oai:tokushima-u.repo.nii.ac.jp:02006258","sets":["1713853213384:1713853295607"]},"author_link":["1602","1599","291","1615","1611"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-02-28","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"86","bibliographicPageStart":"79","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"The Journal of Nursing Investigation","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In order to verify the accuracy of the thickness of the rectus femoris muscle and overlying subcutaneous fat as assessed by ultrasound, experiments were conducted on 10 healthy subjects aged over 30 years to assess the following: 1) concordance of measurements made by two different observers; 2) concordance of repeated measurements made by the same observer ; and 3) concordance of repeated measurements made by the same observer with and without an imaging aid(ultrasound gel block).\nBetween two observers with varying experience in ultrasound, no significant difference in measured muscle thickness was observed ; however, there was a significant difference in subcutaneous fat thickness. When measurements were made by the same observer on two separate days, a significant positive correlation was evident for muscle and subcutaneous fat thickness between the first and second tests. While use of the imaging aid was associated with higher concordance of measurements between the first and second tests, the measurements themselves were affected.\nAlthough ultrasonic measurement of tissue thickness requires further investigation to minimize intra-observer error and examine correlations with other imaging techniques, the accuracy of the measurements in the present study suggests that clinical application may be possible.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"徳島大学医学部","subitem_publisher_language":"ja"}]},"item_10001_source_id_9":{"attribute_name":"収録物ID","attribute_value_mlt":[{"subitem_source_identifier":"13483722","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"24342238","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AA11937122","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1715043197608":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access"}]},"item_1723180141928":{"attribute_name":"EID","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"141756"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"市原, 多香子","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1602","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田村, 綾子","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1599","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"カタオカ, ツヨシ","creatorNameLang":"ja"},{"creatorName":"カタオカ, ツヨシ","creatorNameLang":"ja-Kana"},{"creatorName":"Kataoka, Tsuyoshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"森本, 忠興","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"291","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"南川, 貴子","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1615","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"桑村, 由美","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1611","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2019-04-05"}],"displaytype":"detail","filename":"jni_4_2_79.pdf","filesize":[{"value":"602 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://tokushima-u.repo.nii.ac.jp/record/2006258/files/jni_4_2_79.pdf"},"version_id":"287bfd1e-1ad6-4aaf-8f77-ce77edeadc97"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"leg muscle thickness","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"leg subcutaneous fat thickness","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ultrasonography","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Accuracy of tissue thickness of the rectus femoris region as measured by ultrasound","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Accuracy of tissue thickness of the rectus femoris region as measured by ultrasound","subitem_title_language":"en"}]},"item_type_id":"40001","owner":"7","path":["1713853295607"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-04-05"},"publish_date":"2019-04-05","publish_status":"0","recid":"2006258","relation_version_is_last":true,"title":["Accuracy of tissue thickness of the rectus femoris region as measured by ultrasound"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2024-10-28T08:29:33.978815+00:00"}