{"created":"2024-10-29T00:51:17.243221+00:00","id":2006684,"links":{},"metadata":{"_buckets":{"deposit":"eda187b2-a9b6-4c74-a417-77bff6c2b117"},"_deposit":{"created_by":7,"id":"2006684","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"2006684"},"status":"published"},"_oai":{"id":"oai:tokushima-u.repo.nii.ac.jp:02006684","sets":["1713853213384:1713853295607"]},"author_link":["502","1592","1518"],"item_10001_alternative_title_1":{"attribute_name":"タイトル別表記","attribute_value_mlt":[{"subitem_alternative_title":"Proposal of a Cloud Chamber Experiment Using Diagnostic X-ray Apparatus and an Analysis Assisted by a Simulation Code","subitem_alternative_title_language":"en"}]},"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-04-20","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"392","bibliographicPageStart":"386","bibliographicVolumeNumber":"69","bibliographic_titles":[{"bibliographic_title":"日本放射線技術学会雑誌","bibliographic_titleLang":"ja"},{"bibliographic_title":"Japanese Journal of Radiological Technology","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A cloud chamber is a radiation detector that can visualize the tracks of charged particles. In this study, we developed a middle-type cloud chamber for use in practical training using a diagnostic X-ray apparatus. Because our cloud chamber has a heater to vaporize ethanol and features antifogging glass, it is possible to observe the vapor trails for a long time without the need for fine adjustments. X-rays with a tube voltage of 40 kV or of 120 kV (with a 21-mm aluminum filter) were irradiated at the chamber and the various phenomena were observed. We explain these phenomena in terms of the range of electrons and/or interactions between X-rays and matter and conclude that our analysis is consistent with analysis using the Monte Carlo simulation code EGS5.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本放射線技術学会","subitem_publisher_language":"ja"}]},"item_10001_source_id_9":{"attribute_name":"収録物ID","attribute_value_mlt":[{"subitem_source_identifier":"03694305","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"18814883","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AN00197784","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1715043197608":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access"}]},"item_1722929371688":{"attribute_name":"出版社版DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_language":"ja","subitem_relation_name_text":"10.6009/jjrt.2013_JSRT_69.4.386"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.6009/jjrt.2013_JSRT_69.4.386","subitem_relation_type_select":"DOI"}}]},"item_1723180141928":{"attribute_name":"EID","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"259776"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"林, 裕晃","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"502","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"花光, 宏樹","creatorNameLang":"ja"},{"creatorName":"ハナミツ, ヒロキ","creatorNameLang":"ja-Kana"},{"creatorName":"Hanamitsu, Hiroki","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"西原, 貞光","creatorNameLang":"ja"},{"creatorName":"ニシハラ, サダミツ","creatorNameLang":"ja-Kana"},{"creatorName":"Nishihara, Sadamitsu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"上野, 淳二","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1592","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三好, 弘一","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1518","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2019-09-17"}],"displaytype":"detail","filename":"jjrt_69_4_386.pdf","filesize":[{"value":"1.36 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://tokushima-u.repo.nii.ac.jp/record/2006684/files/jjrt_69_4_386.pdf"},"version_id":"8839732e-4445-4918-aa59-08b8032123aa"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"cloud chamber","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"radioisotopes","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"X-ray","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"practical training","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"診断用X線装置を用いた霧箱実験の提案とシミュレーションコードを援用した解析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"診断用X線装置を用いた霧箱実験の提案とシミュレーションコードを援用した解析","subitem_title_language":"ja"}]},"item_type_id":"40001","owner":"7","path":["1713853295607"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-09-17"},"publish_date":"2019-09-17","publish_status":"0","recid":"2006684","relation_version_is_last":true,"title":["診断用X線装置を用いた霧箱実験の提案とシミュレーションコードを援用した解析"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2024-10-29T00:51:25.939701+00:00"}