{"created":"2024-10-30T09:09:55.625764+00:00","id":2007266,"links":{},"metadata":{"_buckets":{"deposit":"62f1dda5-3e24-43fa-aabf-2e39e2003389"},"_deposit":{"created_by":7,"id":"2007266","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"2007266"},"status":"published"},"_oai":{"id":"oai:tokushima-u.repo.nii.ac.jp:02007266","sets":["1713853213384:1713853295607"]},"author_link":["273"],"item_10001_alternative_title_1":{"attribute_name":"タイトル別表記","attribute_value_mlt":[{"subitem_alternative_title":"Post-column concentration of anions using Nafion membrane tubing","subitem_alternative_title_language":"en"}]},"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"80","bibliographicPageStart":"77","bibliographicVolumeNumber":"34","bibliographic_titles":[{"bibliographic_title":"Journal of Flow Injection Analysis","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this tutorial review, the principle of on-line sample concentration by evaporation through a Nafion membrane tubing and its application to post-column concentration of anions by ion chromatography are described. As solution flows through the Nafion membrane tubing, drying nitrogen gas flows outside it to remove the solvent. The removal rate was increased with increasing sample residence time, drying gas flow rate, and device temperature. With the concentrator, the detection sensibility was improved, and the lower detection limit was obtained compared to that without the concentrator. The optimized system has successfully been applied to the determinations of perchrolate in atmospheric aerosol and orotic acid in urinary samples.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本分析化学会フローインジェクション分析研究懇談会","subitem_publisher_language":"ja"}]},"item_10001_source_id_9":{"attribute_name":"収録物ID","attribute_value_mlt":[{"subitem_source_identifier":"0911775X","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"24337374","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AA10962565","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1715043197608":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access"}]},"item_1722929371688":{"attribute_name":"出版社版DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_language":"ja","subitem_relation_name_text":"10.24688/jfia.34.2_77"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.24688/jfia.34.2_77","subitem_relation_type_select":"DOI"}}]},"item_1723180141928":{"attribute_name":"EID","attribute_value_mlt":[{"subitem_identifier_type":"URI","subitem_identifier_uri":"338080"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"竹内, 政樹","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"273","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2020-02-28"}],"displaytype":"detail","filename":"jfia_34_2_77.pdf","filesize":[{"value":"1.28 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://tokushima-u.repo.nii.ac.jp/record/2007266/files/jfia_34_2_77.pdf"},"version_id":"5e461f61-bb0f-488e-b04d-9185c9434464"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"online-concentration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"anion","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ion chromatography","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Nafion membrane tubing","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Nafionチューブを用いたイオン成分のポストカラム濃縮","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Nafionチューブを用いたイオン成分のポストカラム濃縮","subitem_title_language":"ja"}]},"item_type_id":"40001","owner":"7","path":["1713853295607"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-02-28"},"publish_date":"2020-02-28","publish_status":"0","recid":"2007266","relation_version_is_last":true,"title":["Nafionチューブを用いたイオン成分のポストカラム濃縮"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2024-10-30T09:10:03.812778+00:00"}