{"created":"2024-11-22T06:49:53.432774+00:00","id":2008294,"links":{},"metadata":{"_buckets":{"deposit":"94b82458-050b-4d8d-93ac-62f41dabf5bb"},"_deposit":{"created_by":7,"id":"2008294","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"2008294"},"status":"published"},"_oai":{"id":"oai:tokushima-u.repo.nii.ac.jp:02008294","sets":["1713829974766:1713854682253:1716422247219:1716422749171","1713853213384:1713853295607"]},"author_link":["1645","1572","287"],"item_10001_alternative_title_1":{"attribute_name":"タイトル別表記","attribute_value_mlt":[{"subitem_alternative_title":"Assessment of accidental events in images during capsule endoscopy","subitem_alternative_title_language":"en"},{"subitem_alternative_title":"カプセル内視鏡における画像不良","subitem_alternative_title_language":"ja"}]},"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-08-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3-4","bibliographicPageEnd":"164","bibliographicPageStart":"159","bibliographicVolumeNumber":"76","bibliographic_titles":[{"bibliographic_title":"四国医学雑誌","bibliographic_titleLang":"ja"},{"bibliographic_title":"Shikoku Acta Medica","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Recently, there have been some reports of electromagnetic interference during capsule endoscopy(CE)in regards to other medical devices and facility environment. These accidental events have not been analyzed sufficiently although academic societies and related ministries are proposing guidelines with cautious attention. Based on this, detailed analyses and development of solution are required. In this study, we review our experience with cases of accidental events during CE and assessed the causes and preventive solutions. A total of149CE cases(male :89, female :60, mean age :56±18.8)from January 2017 until December 2019 were analyzed retrospectively. Four cases(2%)with defective images were noted. Detailed events were as follows ;1 disorder of the sensor array, 2 recorder freezes, and 1 electromagnetic interference. These mechanical and electromagnetic troubles should be assessed and shared among medical staffs and manufacturers to propose possible solutions and perform CE safely.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"徳島医学会","subitem_publisher_language":"ja"}]},"item_10001_source_id_9":{"attribute_name":"収録物ID","attribute_value_mlt":[{"subitem_source_identifier":"00373699","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"AN00102041","subitem_source_identifier_type":"NCID"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1715043197608":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"藤井, 有美子","creatorNameLang":"ja"},{"creatorName":"フジイ, ユミコ","creatorNameLang":"ja-Kana"},{"creatorName":"Fujii, Yumiko","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"小林, 誠司","creatorNameLang":"ja"},{"creatorName":"コバヤシ, セイジ","creatorNameLang":"ja-Kana"},{"creatorName":"Kobayashi, Seiji","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"大西, 芳明","creatorNameLang":"ja"},{"creatorName":"オオニシ, ヨシアキ","creatorNameLang":"ja-Kana"},{"creatorName":"Ohnishi, Yoshiaki","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"田中, 克哉","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1645","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"六車, 直樹","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1572","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高山, 哲治","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"287","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2020-10-20"}],"displaytype":"detail","filename":"sam_76_3-4_159.pdf","filesize":[{"value":"1.58 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://tokushima-u.repo.nii.ac.jp/record/2008294/files/sam_76_3-4_159.pdf"},"version_id":"420ba415-b588-49e6-b3ca-6b3ac94edf3b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Capsule endoscopy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Image defect","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Electromagnetic interference","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"当院におけるカプセル内視鏡検査の画像不良事例と対策について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"当院におけるカプセル内視鏡検査の画像不良事例と対策について","subitem_title_language":"ja"}]},"item_type_id":"40001","owner":"7","path":["1713853295607","1716422749171"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-10-20"},"publish_date":"2020-10-20","publish_status":"0","recid":"2008294","relation_version_is_last":true,"title":["当院におけるカプセル内視鏡検査の画像不良事例と対策について"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2024-11-22T06:50:01.762273+00:00"}