Item type |
文献 / Documents(1) |
公開日 |
2015-07-29 |
アクセス権 |
|
|
アクセス権 |
open access |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
タイトル |
|
|
タイトル |
Usefulness of continuous blood glucose monitoring and control for patients undergoing liver transplantation |
|
言語 |
en |
著者 |
オカダ, ツヨシ
川人, 伸次
箕田, 直治
松久, 宗英
北畑, 洋
島田, 光生
大下, 修造
|
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Background : The purpose of this study was to evaluate the usefulness of the closed-loop system (STG-22 ; Nikkiso, Tokyo, Japan), a type of artificial endocrine pancreas for the continuous monitoring and control of intraoperative blood glucose in patients undergoing liver transplantation. Methods : Sixteen patients undergoing livingdonor liver transplantation were enrolled in this study. Glucose levels were controlled with either a manual injection of insulin based on a commonly used sliding scale (manual insulin group, n=8) or a programmed infusion of insulin determined by the control algorithm of the artificial endocrine pancreas (programmed insulin group, n=8). The target glucose level range was set at 80-150 mg/dl. Results : The mean and SD of blood glucose concentration during surgery (Glu-Ave and Glu-SD, respectively) for the programmed insulin group were lower than for the manual insulin group. The coefficient of variability (Glu-CV=Glu-SD×100 /Glu-Ave) for the programmed insulin group was also lower than for the manual insulin group (20.1±4.9% vs. 26.9±6.1% ; mean±SD). No hypoglycemia was detected in either group. Conclusion : The STG-22 closed-loop system is effective for maintaining strict blood glucose control during liver transplantation with minimal variability in blood glucose concentration. |
|
言語 |
en |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
continuous blood glucose monitoring |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
intensive insulin therapy |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
liver transplantation |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
glucose toxicity |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
artificial endocrine pancreas |
書誌情報 |
en : The journal of medical investigation : JMI
巻 60,
号 3-4,
p. 205-212,
発行日 2013-08
|
収録物ID |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
13431420 |
収録物ID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA11166929 |
EID |
|
|
識別子 |
278783 |
|
識別子タイプ |
URI |
言語 |
|
|
言語 |
eng |