WEKO3
アイテム
肺葉切除における電動式自動縫合器の使用経験
https://tokushima-u.repo.nii.ac.jp/records/2002985
https://tokushima-u.repo.nii.ac.jp/records/20029859fdbdbeb-094c-48fe-be69-2da27dc39de2
名前 / ファイル | ライセンス | アクション |
---|---|---|
LID201607212002.pdf (550 KB)
|
|
Item type | 文献 / Documents(1) | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2016-07-21 | |||||||||||||||||||||||
アクセス権 | ||||||||||||||||||||||||
アクセス権 | open access | |||||||||||||||||||||||
資源タイプ | ||||||||||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||
資源タイプ | journal article | |||||||||||||||||||||||
出版タイプ | ||||||||||||||||||||||||
出版タイプ | VoR | |||||||||||||||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||||||||||||
タイトル | ||||||||||||||||||||||||
タイトル | 肺葉切除における電動式自動縫合器の使用経験 | |||||||||||||||||||||||
言語 | ja | |||||||||||||||||||||||
タイトル | ||||||||||||||||||||||||
タイトル | ハイヨウ セツジョ ニオケル デンドウシキ ジドウ ホウゴウキ ノ シヨウ ケイケン | |||||||||||||||||||||||
言語 | ja-Kana | |||||||||||||||||||||||
タイトル別表記 | ||||||||||||||||||||||||
その他のタイトル | Evaluation of Powered ECHELON FLEX for pulmonary lobectomy | |||||||||||||||||||||||
言語 | en | |||||||||||||||||||||||
著者 |
坪井, 光弘
× 坪井, 光弘× 先山, 正二
× 住友, 弘幸
× 坂本, 晋一× 梶浦, 耕一郎× 鳥羽, 博明× 中川, 靖士
× 川上, 行奎× 滝沢, 宏光× 近藤, 和也× 丹黒, 章 |
|||||||||||||||||||||||
抄録 | ||||||||||||||||||||||||
内容記述タイプ | Abstract | |||||||||||||||||||||||
内容記述 | Objective : It has been accepted to use staplers for open and video-assisted thoracic surgery, however there was a risk in stapling of the pulmonary vasculatures. A newly developed stapler, powered ECHELON FLEX (Ethicon) is an electrically-powered stapler. It may reduce tip movement during cutting and stapling, which results in reduction of the risk of trauma to surrounding tissue. The aim of this study was to evaluate powered ECHELON FLEX for pulmonary lobectomy. Methods : We reviewed 16 patients who underwent pulmonary lobectomy with powered ECHELON FLEX in our institution from December, 2013 to April, 2014. Results : There were 25 stapling for the pulmonary artery, 17 stapling for the pulmonary vein, 16 stapling for the bronchus, and 33 stapling for the pulmonary parenchyma. Though two case of oozing from the stamps of a pulmonary artery and pulmonary parenchyma, there were no serious complications related to use of the staplers. Conclusions : The powered ECHELON FLEX can be used for pulmonary lobectomy safely. |
|||||||||||||||||||||||
言語 | en | |||||||||||||||||||||||
キーワード | ||||||||||||||||||||||||
言語 | en | |||||||||||||||||||||||
主題Scheme | Other | |||||||||||||||||||||||
主題 | pulmonary lobectomy | |||||||||||||||||||||||
キーワード | ||||||||||||||||||||||||
言語 | en | |||||||||||||||||||||||
主題Scheme | Other | |||||||||||||||||||||||
主題 | powered stapler | |||||||||||||||||||||||
書誌情報 |
ja : 四国医学雑誌 巻 70, 号 3-4, p. 57-60, 発行日 2014-08-25 |
|||||||||||||||||||||||
収録物ID | ||||||||||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||||||||||
収録物識別子 | 00373699 | |||||||||||||||||||||||
収録物ID | ||||||||||||||||||||||||
収録物識別子タイプ | NCID | |||||||||||||||||||||||
収録物識別子 | AN00102041 | |||||||||||||||||||||||
出版者 | ||||||||||||||||||||||||
出版者 | 徳島医学会 | |||||||||||||||||||||||
言語 | ja | |||||||||||||||||||||||
EID | ||||||||||||||||||||||||
識別子 | 301022 | |||||||||||||||||||||||
識別子タイプ | URI | |||||||||||||||||||||||
言語 | ||||||||||||||||||||||||
言語 | jpn |