Item type |
文献 / Documents(1) |
公開日 |
2018-05-22 |
アクセス権 |
|
|
アクセス権 |
open access |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
出版社版DOI |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.2152/jmi.62.219 |
|
|
言語 |
ja |
|
|
関連名称 |
10.2152/jmi.62.219 |
出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
タイトル |
|
|
タイトル |
Forearm lengthening by distraction osteogenesis : A report on 5 limbs in 3 cases |
|
言語 |
en |
著者 |
殿谷, 一朗
髙橋, 光彦
筒井, 貴彦
後東, 知宏
浜田, 大輔
鈴江, 直人
松浦, 哲也
安井, 夏生
西良, 浩一
|
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Radioulnar length discrepancy causes pain and decreases function of the wrist, forearm, and elbow. Limb lengthening, which has been used in the treatment of various deformities of the forearm, is necessary to restore balance between the ulna and radius. We treated 5 limbs in 3 patients (2 boys, 1 girl ; mean age 9.3 years old) with radioulnar length discrepancy by distraction osteogenesis of either the ulna or radius using external fixators. We dissected the interosseous membrane between the ulna and radius in 3 limbs in 2 cases and did not do so in 2 limbs of 1 case. These cases include 2 cases with hereditary multiple exostoses, and 1 case with multiple epiphyseal dysplasia. The results were investigated and evaluated in this study, using appropriate clinical and radiographic parameters, noting the state of the interosseous membrane, which has an important role in forearm stability. The mean fixation period was 113 days. The mean distraction distance was 22.8 mm. The mean follow-up period was 637.7 days. The mean ulnar shortening and radial articular angle respectively improved from 7.4 mm and 30.2° preoperatively to -0.1 mm and 34.8° postoperatively. Balance between the ulna and radius was restored, and the results showed significant improvements in range of motion of the joints. However, 2 unintended radial head subluxations occurred in 2 limbs without dissection of the interosseous membrane. In addition, a keloid remained in 1 limb due to pin site infection. Forearm lengthening by distraction osteogenesis was useful in our cases. It is important to recognize the function of the interosseous membrane when lengthening is performed by osteotomy of the proximal ulna by gradual distraction with an external fixator. |
|
言語 |
en |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
distraction osteogenesis |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
forearm |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
lengthening |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
interosseous membrane |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
external fixator |
書誌情報 |
en : The Journal of Medical Investigation
巻 62,
号 3-4,
p. 219-222,
発行日 2015-08
|
収録物ID |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
13496867 |
収録物ID |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
13431420 |
収録物ID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA11166929 |
収録物ID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA12022913 |
出版者 |
|
|
出版者 |
Faculty of Medicine Tokushima University |
|
言語 |
en |
EID |
|
|
識別子 |
304935 |
|
識別子タイプ |
URI |
言語 |
|
|
言語 |
eng |