Can intraoperative kinematic analysis predict postoperative kinematics following total knee arthroplasty? A preliminary study

https://tokushima-u.repo.nii.ac.jp/records/2004569
https://tokushima-u.repo.nii.ac.jp/records/2004569
f4880437-3dca-4592-bc9a-33050800c94e
名前 / ファイル ライセンス アクション
jmi_65_1-2_21.pdf jmi_65_1-2_21.pdf (1.39 MB)
Item type 文献 / Documents(1)
公開日 2018-04-27
アクセス権
アクセス権 open access
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版社版DOI
関連識別子 https://doi.org/10.2152/jmi.65.21
関連名称 10.2152/jmi.65.21
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
タイトル
タイトル Can intraoperative kinematic analysis predict postoperative kinematics following total knee arthroplasty? A preliminary study
著者 和田, 佳三

× 和田, 佳三

WEKO 903
徳島大学 教育研究者総覧 334787/profile-ja.html

ja 和田, 佳三
ISNI

ja-Kana ワダ, ケイゾウ

en Wada, Keizo

Search repository
ミカミ, ヒロシ

× ミカミ, ヒロシ

ja ミカミ, ヒロシ

ja-Kana ミカミ, ヒロシ

en Mikami, Hiroshi

Search repository
浜田, 大輔

× 浜田, 大輔

WEKO 447
e-Rad 90380097

ja 浜田, 大輔
ISNI

ja-Kana ハマダ, ダイスケ

en Hamada, Daisuke

Search repository
ヤマザキ, タカハル

× ヤマザキ, タカハル

ja ヤマザキ, タカハル

ja-Kana ヤマザキ, タカハル

en Yamazaki, Takaharu

Search repository
トミタ, テツヤ

× トミタ, テツヤ

ja トミタ, テツヤ

ja-Kana トミタ, テツヤ

en Tomita, Tetsuya

Search repository
西良, 浩一

× 西良, 浩一

WEKO 1543
徳島大学 教育研究者総覧 60063/profile-ja.html
e-Rad 10304528

ja 西良, 浩一
ISNI

ja-Kana サイリョウ, コウイチ

en Sairyo, Koichi

Search repository
抄録
内容記述 The preliminary study analyzed the relationship between intraoperative navigation-based kinematics and postoperative 2-dimensional/3-dimensional (2D/3D) image registration-based kinematics in total knee arthroplasty (TKA). Six knees in 5 patients were analyzed. All TKA procedures were performed using an image-free knee navigation system. Tibial internal rotation was assessed by intraoperative knee kinematics. At 1 year after surgery, tibial internal rotation was evaluated using a 2D/3D image registration technique under loaded and unloaded conditions. The correlation between intraoperative and postoperative data for the tibial internal rotation angle at 10° increments of knee flexion was then assessed. Difference in the knee flexion angle between the intraoperative and postoperative evaluations was adjusted to account for the sagittal cutting angle of the distal femur and proximal tibia. A correlation was found between the intraoperative and postoperative data for loaded knee flexion with this adjustment (Pearson’s r = 0.725, p = 0.012). However, intraoperative kinematics was not significantly correlated with postoperative kinematics in the absence of loading. Larger adequately powered prospective studies are now needed to confirm our preliminary finding that postoperative loaded kinematics can be predicted by intraoperative evaluation.
キーワード
主題 intraoperative analysis
キーワード
主題 postoperative analysis
キーワード
主題 knee arthroplasty
キーワード
主題 kinematics
キーワード
主題 navigation system
書誌情報 en : The Journal of Medical Investigation

巻 65, 号 1-2, p. 21-26, 発行日 2018-02
収録物ID
収録物識別子タイプ ISSN
収録物識別子 13496867
収録物ID
収録物識別子タイプ ISSN
収録物識別子 13431420
収録物ID
収録物識別子タイプ NCID
収録物識別子 AA11166929
収録物ID
収録物識別子タイプ NCID
収録物識別子 AA12022913
出版者
出版者 Faculty of Medicine Tokushima University
EID
識別子 340865
言語
言語 eng
戻る
0
views
See details
Views

Versions

Ver.1 2024-10-28 03:26:06.117609
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3