WEKO3
-
RootNode
アイテム
Usefulness of the SNR Using the Subtraction Method and Image Visibility Using the Howlett Chart Method in X-ray Fluoroscopic System
https://tokushima-u.repo.nii.ac.jp/records/2006682
https://tokushima-u.repo.nii.ac.jp/records/2006682a891953e-e971-421e-8b60-4b9935f2a38b
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 文献 / Documents(1) | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2019-09-17 | |||||||||||||||||||||||||||||
アクセス権 | ||||||||||||||||||||||||||||||
アクセス権 | open access | |||||||||||||||||||||||||||||
資源タイプ | ||||||||||||||||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||||||||
資源タイプ | journal article | |||||||||||||||||||||||||||||
出版社版DOI | ||||||||||||||||||||||||||||||
関連識別子 | https://doi.org/10.4236/ojmi.2014.42007 | |||||||||||||||||||||||||||||
関連名称 | 10.4236/ojmi.2014.42007 | |||||||||||||||||||||||||||||
出版タイプ | ||||||||||||||||||||||||||||||
出版タイプ | VoR | |||||||||||||||||||||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||||||||||||||||||
タイトル | ||||||||||||||||||||||||||||||
タイトル | Usefulness of the SNR Using the Subtraction Method and Image Visibility Using the Howlett Chart Method in X-ray Fluoroscopic System | |||||||||||||||||||||||||||||
著者 |
西原, 貞光
× 西原, 貞光
× ヤマシタ, ユウキ
× カワイ, ナオキ
× 大塚, 秀樹
WEKO
1642
|
|||||||||||||||||||||||||||||
抄録 | ||||||||||||||||||||||||||||||
内容記述 | X-ray fluoroscopy has been used not only for diagnoses but also for treatment, as in interventional radiology. The aim of this study is to assess the usefulness of the signal-to-noise ratio (SNR) using the subtraction method, which is used in the quality assurance/quality control (QA/QC) of magnetic resonance imaging (MRI) equipment, and image visibility using the Howlett chart method in the fluoroscopic examination. The fluoroscopy unit has a detector with an image intensifier and a color liquid crystal display. A 2620 dosimeter and an ionization chamber were selected for the dose measurement. Fluoroscopic images for visual and physical evaluations were collected as dynamic data. The skin surface absorbed dose rates for each tube current were measured using a dosimeter. The SNR using the subtraction method and image visibility using the Howlett chart method were examined. The results from both indicate that as the SNR improves, visual evaluation increases, but the rate of increase gradually saturates. Therefore, physical and visual evaluations are possible with the SNR using the subtraction method and the image visibility using the Howlett chart method. | |||||||||||||||||||||||||||||
キーワード | ||||||||||||||||||||||||||||||
主題 | X-Ray Fluoroscopic System | |||||||||||||||||||||||||||||
キーワード | ||||||||||||||||||||||||||||||
主題 | Signal-to-Noise Ratio | |||||||||||||||||||||||||||||
キーワード | ||||||||||||||||||||||||||||||
主題 | Howlett Chart | |||||||||||||||||||||||||||||
キーワード | ||||||||||||||||||||||||||||||
主題 | Visibility | |||||||||||||||||||||||||||||
書誌情報 |
en : Open Journal of Medical Imaging 巻 4, 号 2, p. 49-56, 発行日 2014-06-04 |
|||||||||||||||||||||||||||||
収録物ID | ||||||||||||||||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||||||||||||||||
収録物識別子 | 21642788 | |||||||||||||||||||||||||||||
収録物ID | ||||||||||||||||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||||||||||||||||
収録物識別子 | 21642796 | |||||||||||||||||||||||||||||
出版者 | ||||||||||||||||||||||||||||||
出版者 | Scientific Research | |||||||||||||||||||||||||||||
権利情報 | ||||||||||||||||||||||||||||||
権利情報 | Copyright © 2014 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/ |
|||||||||||||||||||||||||||||
EID | ||||||||||||||||||||||||||||||
識別子 | 277596 | |||||||||||||||||||||||||||||
言語 | ||||||||||||||||||||||||||||||
言語 | eng |