Monitoring of muscle mass in critically ill patients : comparison of ultrasound and two bioelectrical impedance analysis devices

https://tokushima-u.repo.nii.ac.jp/records/2007478
https://tokushima-u.repo.nii.ac.jp/records/2007478
55e07d82-bd0f-4ac2-8ad5-cb54385b436e
名前 / ファイル ライセンス アクション
jintcare_7_61.pdf jintcare_7_61.pdf (966 KB)
license.icon
Item type 文献 / Documents(1)
公開日 2020-12-07
アクセス権
アクセス権 open access
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版社版DOI
関連識別子 https://doi.org/10.1186/s40560-019-0416-y
関連名称 10.1186/s40560-019-0416-y
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
タイトル
タイトル Monitoring of muscle mass in critically ill patients : comparison of ultrasound and two bioelectrical impedance analysis devices
著者 中西, 信人

× 中西, 信人

ja 中西, 信人

ja-Kana ナカニシ, ノブト

en Nakanishi, Nobuto

Search repository
堤, 理恵

× 堤, 理恵

WEKO 428
徳島大学 教育研究者総覧 207524/profile-ja.html
e-Rad 80510172

ja 堤, 理恵
ISNI

ja-Kana ツツミ, リエ

en Tsutsumi, Rie

Search repository
オカヤマ, ヨシヒロ

× オカヤマ, ヨシヒロ

ja オカヤマ, ヨシヒロ

ja-Kana オカヤマ, ヨシヒロ

en Okayama, Yoshihiro

Search repository
髙島, 拓也

× 髙島, 拓也

WEKO 1516
徳島大学 教育研究者総覧 393558/profile-ja.html

ja 髙島, 拓也
ISNI

ja-Kana タカシマ, タクヤ

en Takashima, Takuya

Search repository
上野, 義豊

× 上野, 義豊

WEKO 947

ja 上野, 義豊
ISNI

ja-Kana ウエノ, ヨシトヨ

en Ueno, Yoshitoyo

Search repository
板垣, 大雅

× 板垣, 大雅

WEKO 534
e-Rad 10464116
徳島大学 教育研究者総覧 231242/profile-ja.html

ja 板垣, 大雅
ISNI

ja-Kana イタガキ, タイガ

en Itagaki, Taiga

Search repository
堤, 保夫

× 堤, 保夫

WEKO 343
e-Rad 90523499

ja 堤, 保夫
ISNI

ja-Kana ツツミ, ヤスオ

en Tsutsumi, Yasuo

Search repository
阪上, 浩

× 阪上, 浩

WEKO 365
徳島大学 教育研究者総覧 186826/profile-ja.html
e-Rad 60372645

ja 阪上, 浩
ISNI

ja-Kana サカウエ, ヒロシ

en Sakaue, Hiroshi

Search repository
大藤, 純

× 大藤, 純

WEKO 1193
徳島大学 教育研究者総覧 60684/profile-ja.html
e-Rad 40346606

ja 大藤, 純
ISNI

ja-Kana オオトウ, ジュン

en Oto, Jun

Search repository
抄録
内容記述 Background: Skeletal muscle atrophy commonly occurs in critically ill patients, and decreased muscle mass is associated with worse clinical outcomes. Muscle mass can be assessed using various tools, including ultrasound and bioelectrical impedance analysis (BIA). However, the effectiveness of muscle mass monitoring is unclear in critically ill patients. This study was conducted to compare ultrasound and BIA for the monitoring of muscle mass in critically ill patients.
Methods: We recruited adult patients who were expected to undergo mechanical ventilation for > 48 h and to remain in the intensive care unit (ICU) for > 5 days. On days 1, 3, 5, 7, and 10, muscle mass was evaluated using an ultrasound and two BIA devices (Bioscan: Malton International, England; Physion: Nippon Shooter, Japan). The influence of fluid balance was also evaluated between each measurement day.
Results: We analyzed 93 images in 21 patients. The age of the patients was 69 (interquartile range, IQR, 59–74) years, with 16 men and 5 women. The length of ICU stay was 11 days (IQR, 9–25 days). The muscle mass, monitored by ultrasound, decreased progressively by 9.2% (95% confidence interval (CI), 5.9–12.5%), 12.7% (95% CI, 9.3–16.1%), 18.2% (95% CI, 14.7–21.6%), and 21.8% (95% CI, 17.9–25.7%) on days 3, 5, 7, and 10 (p < 0.01), respectively, with no influence of fluid balance (r = 0.04, p = 0.74). The muscle mass did not decrease significantly in both the BIA devices (Bioscan, p = 0.14; Physion, p = 0.60), and an influence of fluid balance was observed (Bioscan, r = 0.37, p < 0.01; Physion, r = 0.51, p < 0.01). The muscle mass assessment at one point between ultrasound and BIA was moderately correlated (Bioscan, r = 0.51, p < 0.01; Physion, r = 0.37, p < 0.01), but the change of muscle mass in the same patient did not correlate between these two devices (Bioscan, r = − 0.05, p = 0.69; Physion, r = 0.23, p = 0.07).
Conclusions: Ultrasound is suitable for sequential monitoring of muscle atrophy in critically ill patients. Monitoring by BIA should be carefully interpreted owing to the influence of fluid change.
キーワード
主題 Muscle mass
キーワード
主題 Ultrasound
キーワード
主題 Bioelectrical impedance analysis
キーワード
主題 Fluid balance
キーワード
主題 Critically ill patients
書誌情報 en : Journal of Intensive Care

巻 7, p. 61, 発行日 2019-12-16
収録物ID
収録物識別子タイプ ISSN
収録物識別子 20520492
出版者
出版者 BioMed Central
出版者
出版者 Springer Nature
権利情報
権利情報 © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
EID
識別子 361088
言語
言語 eng
戻る
0
views
See details
Views

Versions

Ver.1 2024-10-30 09:27:35.106225
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3