ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 資料タイプ別
  2. 学術雑誌論文

Vertebral Lateral Notch as Optimal Entry Point for Lateral Mass Screwing Using Modified Roy-Camille Technique

https://tokushima-u.repo.nii.ac.jp/records/2007932
https://tokushima-u.repo.nii.ac.jp/records/2007932
d769c113-c900-4d4b-aaaa-9fab877f4d8f
名前 / ファイル ライセンス アクション
asj_12_2_272.pdf asj_12_2_272.pdf (880 KB)
license.icon
アイテムタイプ 文献 / Documents(1)
公開日 2020-08-31
アクセス権
アクセス権 open access
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版社版DOI
関連識別子 https://doi.org/10.4184/asj.2018.12.2.272
関連名称 10.4184/asj.2018.12.2.272
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
タイトル
タイトル Vertebral Lateral Notch as Optimal Entry Point for Lateral Mass Screwing Using Modified Roy-Camille Technique
タイトル別表記
その他のタイトル Optimal Entry Point for Lateral Mass Screwing
著者 ヤマモト, ノリオ

× ヤマモト, ノリオ

ja ヤマモト, ノリオ

ja-Kana ヤマモト, ノリオ

en Yamamoto, Norio

Search repository
小坂, 浩史

× 小坂, 浩史

ja 小坂, 浩史

ja-Kana コサカ, ヒロフミ

en Kosaka, Hirofumi

Search repository
東野, 恒作

× 東野, 恒作

WEKO 182
e-Rad_Researcher 80380129

ja 東野, 恒作
東野, 恒作
ISNI

ja-Kana ヒガシノ, コウサク
ヒガシノ, コウサク

en Higashino, Kousaku
Higashino, Kousaku

Search repository
森本, 雅俊

× 森本, 雅俊

WEKO 1165
徳島大学 教育研究者総覧 364653/profile-ja.html
e-Rad_Researcher 20748701

ja 森本, 雅俊
森本, 雅俊
ISNI

ja-Kana モリモト, マサトシ
モリモト, マサトシ

en Morimoto, Masatoshi
Morimoto, Masatoshi

Search repository
山下, 一太

× 山下, 一太

WEKO 904

ja 山下, 一太
ISNI

ja-Kana ヤマシタ, カズタ

en Yamashita, Kazuta

Search repository
手束, 文威

× 手束, 文威

WEKO 832
徳島大学 教育研究者総覧 310676/profile-ja.html

ja 手束, 文威
ISNI

ja-Kana テヅカ, フミタケ

en Tezuka, Fumitake

Search repository
林, 二三男

× 林, 二三男

ja 林, 二三男

ja-Kana ハヤシ, フミオ

en Hayashi, Fumio

Search repository
髙田, 洋一郎

× 髙田, 洋一郎

WEKO 551
e-Rad_Researcher 20420549

ja 髙田, 洋一郎
髙田, 洋一郎
ISNI

ja-Kana タカタ, ヨウイチロウ
タカタ, ヨウイチロウ

en Takata, Yoichiro
Takata, Yoichiro

Search repository
酒井, 紀典

× 酒井, 紀典

WEKO 278
徳島大学 教育研究者総覧 165746/profile-ja.html
e-Rad_Researcher 80403731

ja 酒井, 紀典
酒井, 紀典
ISNI

ja-Kana サカイ, トシノリ
サカイ, トシノリ

en Sakai, Toshinori
Sakai, Toshinori

Search repository
長町, 顕弘

× 長町, 顕弘

ja 長町, 顕弘

ja-Kana ナガマチ, アキヒロ

en Nagamachi, Akihiro

Search repository
西良, 浩一

× 西良, 浩一

WEKO 1543
徳島大学 教育研究者総覧 60063/profile-ja.html
e-Rad_Researcher 10304528

ja 西良, 浩一
西良, 浩一
ISNI

ja-Kana サイリョウ, コウイチ
サイリョウ, コウイチ

en Sairyo, Koichi
Sairyo, Koichi

Search repository
抄録
内容記述 Study Design: Retrospective study of 37 consecutive female patients with cervical spondylotic myelopathy who underwent reconstructed computed tomography (CT) scanning of the cervical spine.
Purpose: The purpose of this study was to investigate whether the vertebral lateral notch of the cervical spine is an effective landmark to determine the entry point for lateral mass screwing. A modified Roy-Camille technique was used to determine the entry point associated with the lateral notch of the cervical spine.
Overview of Literature: The Roy-Camille technique has been a popular technique for the posterior fixation of the cervical spine. A problem with this technique is determining the entry point on the lateral mass via visual inspection, such as in cases with degenerative or destructive cervical facet joints.
Methods: Thirty-three female patients with cervical spondylotic myelopathy underwent reconstructed CT scanning of the cervical spine. Overall, 132 vertebrae from C3 to C6 were reviewed using reconstructed CT. The probable trajectory using a modified Roy-Camille technique was determined using reconstructed CT scans, and the optimal entry point was identified. Horizontal and vertical distances from the vertebral lateral notch were measured.
Results: The entry point determined using the modified Roy-Camille technique was significantly superior and medial compared with that determined using the conventional Roy-Camille technique. At C3 and C4 levels, the entry point using the modified technique was 1.4 mm below and 4.4 mm medial to the lateral notch, and at C5 and C6 levels, it was 2.3 mm below and 4.9 mm medial to the lateral notch.
Conclusions: The vertebral lateral notch of the cervical spine was an effective landmark to determine the entry point for lateral mass screwing. The modified Roy-Camille technique proposed here may prevent surgical complications and poor outcomes.
キーワード
主題 Lateral vertebral notch
キーワード
主題 Roy-Camille technique
キーワード
主題 Lateral mass screwing
書誌情報 en : Asian Spine Journal

巻 12, 号 2, p. 272-276, 発行日 2018-04-16
収録物ID
収録物識別子タイプ ISSN
収録物識別子 19761902
収録物ID
収録物識別子タイプ ISSN
収録物識別子 19767846
収録物ID
収録物識別子タイプ NCID
収録物識別子 AA12329596
出版者
出版者 Korean Society of Spine Surgery
権利情報
権利情報 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
EID
識別子 340871
言語
言語 eng
戻る
0
views
See details
Views

Versions

Ver.1 2024-10-30 10:04:26.084327
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3