WEKO3
-
RootNode
アイテム
Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination
https://tokushima-u.repo.nii.ac.jp/records/2009535
https://tokushima-u.repo.nii.ac.jp/records/20095353e002ee1-946c-4bc5-a4a8-0d57530107f9
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 文献 / Documents(1) | |||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2022-02-07 | |||||||||||||||||||||||||||||||||||
アクセス権 | ||||||||||||||||||||||||||||||||||||
アクセス権 | open access | |||||||||||||||||||||||||||||||||||
資源タイプ | ||||||||||||||||||||||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||||||||||||||
資源タイプ | journal article | |||||||||||||||||||||||||||||||||||
出版社版DOI | ||||||||||||||||||||||||||||||||||||
関連識別子 | https://doi.org/10.1038/s41598-021-85060-5 | |||||||||||||||||||||||||||||||||||
関連名称 | 10.1038/s41598-021-85060-5 | |||||||||||||||||||||||||||||||||||
出版タイプ | ||||||||||||||||||||||||||||||||||||
出版タイプ | VoR | |||||||||||||||||||||||||||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||||||||||||||||||||||||
タイトル | ||||||||||||||||||||||||||||||||||||
タイトル | Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination | |||||||||||||||||||||||||||||||||||
著者 |
山下, 一太
× 山下, 一太
WEKO
904
× 東野, 恒作× 林, 裕晃× タケガミ, カズキ
× 林, 二三男
× 鶴尾, 吉宏
WEKO
755
× 西良, 浩一
WEKO
1543
|
|||||||||||||||||||||||||||||||||||
抄録 | ||||||||||||||||||||||||||||||||||||
内容記述 | Ionizing radiation from Computed tomography (CT) examinations and the associated health risks are growing concerns. The purpose of this study was to directly measure individual organ doses during routine clinical CT scanning protocols and to evaluate how these measurements vary with scanning conditions. Optically stimulated luminescence (OSL) dosimeters were surgically implanted into individual organs of fresh non-embalmed whole-body cadavers. Whole-body, head, chest, and abdomen CT scans were taken of 6 cadavers by simulating common clinical methods. The dosimeters were extracted and the radiation exposure doses for each organ were calculated. Average values were used for analysis. Measured individual organ doses for whole-body routine CT protocol were less than 20 mGy for all organs. The measured doses of surface/shallow organs were higher than those of deep organs under the same irradiation conditions. At the same tube voltage and tube current, all internal organ doses were significantly higher for whole-body scans compared with abdominal scans. This study could provide valuable information on individual organ doses and their trends under various scanning conditions. These data could be referenced and used when considering CT examination in daily clinical situations. | |||||||||||||||||||||||||||||||||||
書誌情報 |
en : Scientific Reports 巻 11, p. 5435, 発行日 2021-03-08 |
|||||||||||||||||||||||||||||||||||
収録物ID | ||||||||||||||||||||||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||||||||||||||||||||||
収録物識別子 | 20452322 | |||||||||||||||||||||||||||||||||||
出版者 | ||||||||||||||||||||||||||||||||||||
出版者 | Springer Nature | |||||||||||||||||||||||||||||||||||
権利情報 | ||||||||||||||||||||||||||||||||||||
権利情報 | This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. | |||||||||||||||||||||||||||||||||||
EID | ||||||||||||||||||||||||||||||||||||
識別子 | 376351 | |||||||||||||||||||||||||||||||||||
言語 | ||||||||||||||||||||||||||||||||||||
言語 | eng |