| 抄録 |
|
|
内容記述 |
Objectives: To determine the accuracy of three-dimensional (3D) printed models fabricated from cone-beam computed tomography (CBCT) scans of human mandibular dry skulls in comparison with models derived from intraoral scanner (IOS) data. Materials and Methods: Six human mandibular dry skulls were scanned by IOS and CBCT. Digital models (DMs) constructed from the IOS and CBCT data were fabricated physically using a 3D printer. The width and thickness of individual teeth and intercanine and molar widths were measured using a digital caliper. The accuracy of the DMs was compared between IOS and CBCT. Paired t-tests were used for intergroup comparisons. Results: All intraclass correlation coefficient values for the three measurements (mesial-distal, buccal-lingual, width) exceeded 0.9. For the mandibular teeth, there were significant discrepancies in model accuracy between the IOS (average discrepancies of 0.18 ± 0.08 mm and 0.16 ± 0.12 mm for width and thickness, respectively) and CBCT (0.28 ± 0.07 mm for width, 0.37 ± 0.2 mm for thickness; P < .01). Intercanine (P = .38) and molar widths (P = .41) showed no significant difference between groups. Conclusions: There was a statistically significant difference in the accuracy of DMs obtained from CBCT and IOS; however, this did not seem to result in any important clinical difference. CBCT could be routinely used as an orthodontic diagnostic tool and for appliance construction. |
| キーワード |
|
|
主題 |
3D printed model |
| キーワード |
|
|
主題 |
CBCT |
| 書誌情報 |
en : The Angle Orthodontist
巻 92,
号 6,
p. 722-727,
発行日 2022-07-19
|
| 収録物ID |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
19457103 |
| 収録物ID |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
00033219 |
| 収録物ID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA00525451 |
| 出版者 |
|
|
出版者 |
The EH Angle Education and Research Foundation |
| EID |
|
|
識別子 |
392624 |
| 言語 |
|
|
言語 |
eng |