WEKO3
アイテム
Accuracy of tissue thickness of the rectus femoris region as measured by ultrasound
https://tokushima-u.repo.nii.ac.jp/records/2006258
https://tokushima-u.repo.nii.ac.jp/records/2006258c6079b80-df59-46b0-bc93-1c8bf958ca59
名前 / ファイル | ライセンス | アクション |
---|---|---|
jni_4_2_79.pdf (602 KB)
|
|
Item type | 文献 / Documents(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2019-04-05 | |||||||||||
アクセス権 | ||||||||||||
アクセス権 | open access | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||
資源タイプ | journal article | |||||||||||
出版タイプ | ||||||||||||
出版タイプ | VoR | |||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||
タイトル | ||||||||||||
タイトル | Accuracy of tissue thickness of the rectus femoris region as measured by ultrasound | |||||||||||
言語 | en | |||||||||||
著者 |
市原, 多香子
× 市原, 多香子× 田村, 綾子× カタオカ, ツヨシ
× 森本, 忠興× 南川, 貴子× 桑村, 由美 |
|||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | In order to verify the accuracy of the thickness of the rectus femoris muscle and overlying subcutaneous fat as assessed by ultrasound, experiments were conducted on 10 healthy subjects aged over 30 years to assess the following: 1) concordance of measurements made by two different observers; 2) concordance of repeated measurements made by the same observer ; and 3) concordance of repeated measurements made by the same observer with and without an imaging aid(ultrasound gel block). Between two observers with varying experience in ultrasound, no significant difference in measured muscle thickness was observed ; however, there was a significant difference in subcutaneous fat thickness. When measurements were made by the same observer on two separate days, a significant positive correlation was evident for muscle and subcutaneous fat thickness between the first and second tests. While use of the imaging aid was associated with higher concordance of measurements between the first and second tests, the measurements themselves were affected. Although ultrasonic measurement of tissue thickness requires further investigation to minimize intra-observer error and examine correlations with other imaging techniques, the accuracy of the measurements in the present study suggests that clinical application may be possible. |
|||||||||||
言語 | en | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | leg muscle thickness | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | leg subcutaneous fat thickness | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | ultrasonography | |||||||||||
書誌情報 |
en : The Journal of Nursing Investigation 巻 4, 号 2, p. 79-86, 発行日 2006-02-28 |
|||||||||||
収録物ID | ||||||||||||
収録物識別子タイプ | ISSN | |||||||||||
収録物識別子 | 13483722 | |||||||||||
収録物ID | ||||||||||||
収録物識別子タイプ | ISSN | |||||||||||
収録物識別子 | 24342238 | |||||||||||
収録物ID | ||||||||||||
収録物識別子タイプ | NCID | |||||||||||
収録物識別子 | AA11937122 | |||||||||||
出版者 | ||||||||||||
出版者 | 徳島大学医学部 | |||||||||||
言語 | ja | |||||||||||
EID | ||||||||||||
識別子 | 141756 | |||||||||||
識別子タイプ | URI | |||||||||||
言語 | ||||||||||||
言語 | eng |