36M-pixel synchrotron radiation micro-CT for whole secondary pulmonary lobule visualization from a large human lung specimen |
|
言語 |
en |
著者 |
ウメタニ, ケイジ
オカモト, トシヒロ
サイトウ, クルミ
河田, 佳樹
仁木, 登
|
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
A micro-CT system was developed using a 36M-pixel digital single-lens reflex camera as a cost-effective mode for large human lung specimen imaging. Scientific grade cameras used for biomedical x-ray imaging are much more expensive than consumer-grade cameras. During the past decade, advances in image sensor technology for consumer appliances have spurred the development of biomedical x-ray imaging systems using commercial digital single-lens reflex cameras fitted with high megapixel CMOS image sensors. This micro-CT system is highly specialized for visualizing whole secondary pulmonary lobules in a large human lung specimen. The secondary pulmonary lobule, a fundamental unit of the lung structure, reproduces the lung in miniature. The lung specimen is set in an acrylic cylindrical case of 36 mm diameter and 40 mm height. A field of view (FOV) of the micro-CT is 40.6 mm wide × 15.1 mm high with 3.07 μm pixel size using offset CT scanning for enlargement of the FOV. We constructed a 13,220 × 13,220 × 4912 voxel image with 3.07 μm isotropic voxel size for three-dimensional visualization of the whole secondary pulmonary lobule. Furthermore, synchrotron radiation has proved to be a powerful high-resolution imaging tool. This micro-CT system using a single-lens reflex camera and synchrotron radiation provides practical benefits of high-resolution and wide-field performance, but at low cost. |
|
言語 |
en |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Digital single-lens reflex camera |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Human lung specimen |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Micro-CT |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Secondary pulmonary lobule |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Synchrotron radiation |
書誌情報 |
en : European Journal of Radiology Open
巻 7,
p. 100262,
発行日 2020-09-12
|